Availability: | |
---|---|
PTZT
HAIVOL
The EN 50181 standard pertains to plug-in bushings above 1kV and up to 52kV, with a range of 250A to 2.5kA for equipment that is not liquid-filled transformers. Meanwhile, EN 50180 covers bushings above 1kV and up to 36kV, with a range of 250A to 3.15kA for liquid-filled transformers.
As for HD629.1, it outlines the test requirements for accessories used on power cables with a rated voltage from 3.6/6(7.2)kV up to 20.8/36(42)kV. This is specifically for cables with extruded insulation. Meanwhile, IEC 60502.4 provides test requirements for accessories used on power cables with extruded insulation for rated voltages from 1kV(U=1.2kV) up to 30kV(U=36kV). This pertains to cables with rated voltages from 6kV up to 30kV(U=36kV).
For surge arresters without gaps used in a.c. systems, IEC 60099 and JB/T 8952 cover metal oxide types while IEEE 386 and GB11032 pertain to those without gaps but with different specifications. JB/T 8952 specifically covers polymer-housed metal oxide surge arresters without gaps for a.c. systems.
All of the standards mentioned above involve voltage characteristics.
Elbow type PT connector be used as full insulation, fully shielded, fully sealed connection for JDZ12A-10R Transformer which providing operating power supply or measuring protection for electric operating mechanism.
Applicable for 15kV XLPE cable cross-section of 35mm² ~ 50mm².
Techncial characteristic
1、Ensure its reliability for the full insulation, fully sealed, fully shielded performance,Compare with others,its size is more compact.
2、The test point can be installed with a point of display or fault indicator, in order to display the device is charged and fault status.
3、The inner and outer shield design makes the electric field structure more optimized, the outer shield grounding, effectively keep the outer surface of the cable head zero Potential to ensure personal safety during maintenance operations.
4、The plug can be used between the rear of the cable and shrink tube shrink seal, in order to prevent moisture intrusion cable problems.
Standard packing
Body of Elbow type PT connector
Towels
Instruction Manual
Cap of test point
Crimp Terminals
Earth wire
Conformity certificat
3 pcs/ carton G.W:3kg Carton size:24cm×19cm×21cm
The EN 50181 standard pertains to plug-in bushings above 1kV and up to 52kV, with a range of 250A to 2.5kA for equipment that is not liquid-filled transformers. Meanwhile, EN 50180 covers bushings above 1kV and up to 36kV, with a range of 250A to 3.15kA for liquid-filled transformers.
As for HD629.1, it outlines the test requirements for accessories used on power cables with a rated voltage from 3.6/6(7.2)kV up to 20.8/36(42)kV. This is specifically for cables with extruded insulation. Meanwhile, IEC 60502.4 provides test requirements for accessories used on power cables with extruded insulation for rated voltages from 1kV(U=1.2kV) up to 30kV(U=36kV). This pertains to cables with rated voltages from 6kV up to 30kV(U=36kV).
For surge arresters without gaps used in a.c. systems, IEC 60099 and JB/T 8952 cover metal oxide types while IEEE 386 and GB11032 pertain to those without gaps but with different specifications. JB/T 8952 specifically covers polymer-housed metal oxide surge arresters without gaps for a.c. systems.
All of the standards mentioned above involve voltage characteristics.
Elbow type PT connector be used as full insulation, fully shielded, fully sealed connection for JDZ12A-10R Transformer which providing operating power supply or measuring protection for electric operating mechanism.
Applicable for 15kV XLPE cable cross-section of 35mm² ~ 50mm².
Techncial characteristic
1、Ensure its reliability for the full insulation, fully sealed, fully shielded performance,Compare with others,its size is more compact.
2、The test point can be installed with a point of display or fault indicator, in order to display the device is charged and fault status.
3、The inner and outer shield design makes the electric field structure more optimized, the outer shield grounding, effectively keep the outer surface of the cable head zero Potential to ensure personal safety during maintenance operations.
4、The plug can be used between the rear of the cable and shrink tube shrink seal, in order to prevent moisture intrusion cable problems.
Standard packing
Body of Elbow type PT connector
Towels
Instruction Manual
Cap of test point
Crimp Terminals
Earth wire
Conformity certificat
3 pcs/ carton G.W:3kg Carton size:24cm×19cm×21cm