Insulators are a special insulation control that can play an important role in overhead transmission lines. In the early years, insulators were mostly used for telegraph poles. Slowly, a lot of disk-shaped insulators were hung on one end of the high-voltage wire connection tower. It was used to increase the creepage distance. It was usually made of glass or ceramics and was called an insulator. Insulators should not fail due to various electromechanical stresses caused by changes in the environment and electrical load conditions, otherwise the insulators will not have a significant effect and will damage the use and operating life of the entire line.
The main function of insulators is to achieve electrical insulation and mechanical fixation, for which various electrical and mechanical performance requirements are specified. If under the specified operating voltage, lightning overvoltage and internal overvoltage, no breakdown or flashover along the surface; under the specified long-term and short-term mechanical load, no damage and damage; under the specified machine , After long-term operation under electrical load and various environmental conditions, no obvious deterioration will occur; the fittings of insulators will not produce obvious corona discharge under the operating voltage, so as not to interfere with radio or television reception. Because insulators are widely used devices, their connection fittings are also required to be interchangeable. In addition, the technical standards of insulators also require various electrical, mechanical, physical, and environmental conditions to test the performance and quality of the insulators according to different types and conditions of use.
Specifications
Pin Porcelain Insulators (ANSI BS)
1.voltage:23-69kv
2.creepage distance:330-865mm
3.weight:3.7-13.5kg
4.good use-best price
Pin Porcelain Insulators (ANSI BS series)
Summary
1) Material:porcelain
2) Class BS: P-11-Y P-15-Y P-20-Y P-33-Y
3)pin type insualators for high voltage
4)safe usage
5)various desigins available
6)fast shipping and great service
7)good quality and reasonable price
Main dimensions and standard particulars | ||||||
Fig | 1 | 1 | 2 | 3 | ||
Class BS | P-11-Y | P-15-Y | P-20-Y | P-33-Y | ||
Main Dimensions (mm) | H | 133 | 137 | 195 | 244 | |
h | 48 | 48 | 52.63 | 52.63 | ||
D | 140 | 152 | 230 | 279 | ||
d | 18.29 | 18.29 | 27.78 | 27.78 | ||
R1 | 13 | 13 | 19 | 19 | ||
R2 | 9.5 | 12.7 | 14.3 | 13 | ||
Nominal Voltage (kV) | 11 | 15 | 22 | 33 | ||
Creepage Distance (mm) | 240 | 298 | 432 | 630 | ||
Minimum Flashover Voltage | Power-frequency | Dry (kV) | 75 | 80 | 100 | 135 |
Wet (kV) | 45 | 55 | 60 | 85 | ||
50% Impulse | Positive (kV) | 100 | 130 | 160 | 185 | |
Negative (kV) | 110 | 175 | 205 | |||
Withstand Voltage | One minute power- frequency | Dry (kV) | 65 | 70 | 90 | 110 |
Wet (kV) | 40 | 50 | 55 | 75 | ||
mpulse (kV) | 110 | 150 | ||||
Radio- Influence- Voltage Data | Test Voltage to Ground (kV) | 15 | 15 | 22 | 30 | |
Maximum RIV at 1000kHz (uV) | 8000 | 8000 | 12000 | 16000 | ||
Power-frequency puncture Voltage(kV) | 135 | 135 | 145 | 185 | ||
Cantilever Failing Load(kN) | 11 | 11 | 11 | 13 | ||
Weight (kg) | 1.8 | - | - | 11.5 |
Haivo polymer housed zinc oxide surge arrester has passed the short- circuit test successfully in XIHARI again in 20th of April 2021 (National quality supervision & inspection center for insulator & surge arrester).
Haivo distribution type singlephase outdoor disconnect switch 27KV 100A successfully passed the type test in the lab of China national center for quality supervision and test of electrical apparatus products.
ZHEJIANG Haivo ELECTRICAL CO.,LTD. participated in the 127th Online Canton Fair
Our company received the Award notice of DDLO products on May 6th, which is already the second product we have cooperated with CEB.
We made type test for fuse cutout in KEMA laboratory Prague,Czech Republic in Feb of 2019.
Haivo electrical participated MIDDLE EAST ELECTRICITY EXHIBITION in Dubai world trade centre,UAE from 3-5 March 2020.
Haivo electrical participated in the “ELECRAMA” Exhibition in India from January 18,22,2020.
Haivo polymer housed zinc oxide surge arrester has passed the short- circuit test successfully in XIHARI again in 20th of April 2021 (National quality supervision & inspection center for insulator & surge arrester).The Rated voltage of tested object is 36KV,Its nominal discharge current is 5kA.The t
Haivo polymer housed zinc oxide surge arrester has passed the short- circuit test successfully in XIHARI again in 20th of April 2021 (National quality supervision & inspection center for insulator & surge arrester).The Rated voltage of tested object is 36KV,Its nominal discharge current is 5kA.The t
Email: jonsonchai@chinahaivo.com
Wechat:+86 13587716869
WhatsApp:+86 13587716869
Tel: 0086-577-62836929
0086-577-62836926
0086-13587716869
0086-15957720101